WIMA MKP-Y2

WIMA MKP-Y2

Metallized Polypropylene (PP) RFI-Capacitors Class Y2.

Capacitances from 1000 pF to 1 µF.
Rated Voltage 300 VAC.
PCM 10 mm to 37.5 mm.

Special Features

Reliable self-healing
High degree of interference suppression due to good attenuation and low ESR
AEC-Q200 qualified
According to RoHS 2015/863/EU

Typical Applications
Class Y2 RFI applications to meet EMC regulations

Capacitors connected to the mains between phase or neutral and earthed casing
By-passing of the basic or supplementary insulation, pulse peak voltage < 5 kV

Construction

Dielectric: Polypropylene (PP) film
Capacitor electrodes: Vacuum-deposited
Encapsulation: Solvent-resistant, flame-retardent plastic case with epoxy resin seal, UL 94 V-0
Terminations: Tinned wire
Marking: Colour: Red. Marking: Black.

Internal construction:

Construction WIMA MKP-Y2 capacitors

Electrical Data
Capacitance range: 1000 pF to 1.0 µF
Rated voltage: 300VAC
Continuous DC voltage* (general guide): < 1000V
Capacitance tolerances: ±20%, ±10%, ±5%
Operating temperature range: -55°C to +105°C
Climatic test category: 55/105/56 in accordance with IEC
Passive flammability class:
B for capacitors with V > 1750 mm3
C for capacitors with V < 1750 mm3
Insulation resistance at +20°C:
C < 0.33 µF: > 1.5 x 104 MΩ
C > 0.33 µF: > 5000 sec (MΩ x µF)
Measuring voltage: 100V/1 min.
Dissipation factors at +20°C: tanδ
at f C < 0.1 µF 0.1 µF < C < 1.0 µF
1kHz
10kHz
100kHz < 18 x 10-4
< 20 x 10-4
< 100 x 10-4 < 20 x 10-4
< 60 x 10-4

Test specifications: In accordance with IEC 60384-14
Maximum pulse rise time: 100 V/µsec for pulses equal to a voltage amplitude with √2 x 300VAC = 425V according to IEC 60384-14
Test voltage: 2700VDC, 2sec
Reliability: Operational life > 300000 hours. Failure rate < 2 fit (0.5 x Ur and 40°C)
Approvals:
Country Authority Specification Symbol Approval-No.
Germany

USA/Canada VDE

UL IEC 60384-14/4

UL 60384-14
CAN/CSA-E60384-14 ENEC
UL 40008997

E 134915
* If safety-approved EMI suppression capacitors are operated with a DC voltage being above the specified AC voltage rating the given approvals are no longer valid (IEC 60384-14).
Furthermore the permissible pulse rise time du/dt (Fmax.) will be subject to a reduction according to
Fmax. = Fr x √2 x UAC / UDC
if the DC operating voltage UDC is higher than √2 x UAC
Mechanical Tests
Pull test on pins: 10 N in direction of pins according to IEC 60068-2-21
Vibration: 6 hours at 10…2000Hz and 0.75mm displacement amplitude or 10g in accordance with IEC 60068-2-6
Low air density: 1kPa = 10 mbar in accordance with IEC 60068-2-13
Bump test: 4000 bumps at 390 m/sec2 in accordance with IEC 60068-2-29
Packing